High Pressure Washing and Precision Cleanliness Tester Process
Washing with Hot Alkali,
First Stagnation,
Second rinse,
Manual washing with High Pressure Pump and Manual hand gun,
Manual drying on the platform with drying stand, Drying Drawer and Hand gun,
Manual moving crane system on rail.
Cabin outlet dual filter system, (Size measurable and weight weighable filter system.)
The parts will be fixed on the table inside the machine with the fixture in the specified positions.
After the completion of the whole washing process, the part will be discharged manually.
There will be no accumulation of chips and/or washing liquid in any area of the machine.
There will be a hive where the filter will be placed in the cabin evacuation.
The hive will have a 90 micron washable stainless wire filter at the top and 20 micron below.
Filters will be easy to disassemble and assemble, and size will be measurable and weight can be weighed
| Technical Information Table | HTTC-YB-120-100-100 |
|---|---|
| Thread Dimensions mm | Width-1250- Length-2.350- H-2.500 |
| Washing Cabinet Dimensions | Width-1200- Length-1000- H-1.000 |
| Washing Tank Capacity | 350 Lt |
| First Rinse Tank Capacity | 250 Lt |
| Second Rinsing Tank Capacity | 250 Lt |
| 1-Washing Pump and Pressure | 8- 10 Bar |
| 2-First Rinse Pump | 25 - 29 Bar |
| 3-Second Rinsing Pump | 8 - 10 Bar |
| 4-Drying Air Jet | BLOWER |
| Steam Release | Vacuum Pump |
| Turntable movement | Reducer. |
| Opening the lid | Pneumatic Piston |
| Automatic Water supply- | With solenoid valve |
| CONTROL SYSTEM | PLC CONTROLLED |
| Technical Information Table | HTTC-110-95-110 |
|---|---|
| Thread Dimensions mm | Width-1250- Length-1.500- H-2.000 |
| Washing Cabinet Dimensions | En-1100- Size-950- H-1150 |
| Washing Tank Capacity and Heating | 100 Litres |
| Rinsing Tank Capacity | 100 Litres |
| 1-Washing, NON-RUSTING PUMP | 4.5 bar |
| 2-Rinse, NON-RUST PUMP | 4.5 bar |
| 3-Manual Flushing High Pressure Pump | 60 - Bar |
| 4-Manual Gun Drying | Manual and drawer Drying |
| Cabin Evacuation | Diaphragm Pump |
| Opening the Cover on the sides | Manual hinge and lock |
| Parts Loading and Handling system | Manual moving, winch system. |
| Boiler Heating Control | Automatic Thermostat |
| Control System | PLC and 7" Control panel |
| Automatic Water supply- | With solenoid valve |